Tag Archives: “Earth Tubes”

Waterproofing

0

Posted on August 20, 2014 by

Before we can back-fill against the basement, we needed to clear the area, waterproof and put in the drain tile…  We also needed things like radon tubes and floor drains to exit the building.

My wife, Sherri, had to help a lot this week…  And as she puts it, “It wasn’t princess work!”  I did try to hire some people, especially when I realized I would have to carry down and place the 4 yards of pea stone by bucket, but it didn’t work out and we were on our own.

The video is here…

 

Stripping

I started with stripping the bracing away.  In most cases the wood was perfectly good with only a few screw holes.  I will get to use it all again on the second floor.  Actually, the site has only generated a couple bags of garbage and a box for recycling all summer, and that was mostly lunch trash dropped by the contractors working on the site.

I left the insulation on the side of the window well.  It was meant to be forming, but with an earth sheltered umbrella, it helps to insulate the earth where ever you can.

StripForms

 

WaterproofingGracoMagnum_X7

We bought a power sprayer from home Depot (Graco Magnum X7), which worked pretty well.   We justified the purchase by reminding ourselves how much work it had been to paint the ceilings in our current house when we moved in.  This sprayer will come in handy when we do one last paint before we put our existing house on the market next spring.  As for the current task of spraying on the waterproofing, we saved a lot of time (and got better coverage) by not trying to roll the water proofing over that rough surface.  With only one sprayer, it was a one person job and Sherri took care of it.

As for the water proofing its self, we used ProteShield Elastomeric Waterproofing Sealer.    We actually applied it about 50% thicker than the directions specified.   The instructions said it would dry clear, but we were surprised that it appeared to “disappear” after just a few minutes (and faster on smoother sections of the wall).  It was like it wasn’t even there.

When we got the waterproofing inspected later, the building inspector was concerned about it.  He gave us a “partial” pass, and told us we could proceed at our own risk, but if the waterproofing doesn’t qualify, we will need to dig it up and do it over again.  We proceeded with the back-filling on faith in Home Depot and (later that evening) sent him this technical data sheet, which mentions that it is for above and below grade waterproofing of basements and foundations.  It even says to give it 48 hours to cure before back-filling, we gave it double that.  However, the inspector says it is missing a mention of some specific government tests that would qualify the waterproofing for use as below grade waterproofing.  The inspector is going to try and contact the company to see if they have this documentation, and if not, he is going to insist that we redo it.

Drain tile

I suppose drain tile used to be made of ceramic tiles curved into tubes and then fired.  In hispanic areas, I have seen them use the same tiles they use on the roofs.  These were placed end to end to help carry water away from foundations.  Now days, they are made of HDPE plastic that lasts forever.  Ours was also covered in a nylon sock to keep the sand from clogging it.

Actually, our site doesn’t even really need drain tile.  The sand just lets the water fall thru it, but the building code says we need it and that we need it to be covered in pea stone (an extra cost/hassle that shouldn’t be necessary for such a sandy site).

Another neighbor in the area told me that he put in the drain tile around his house to satisfy the inspection, but then didn’t actually run it to anywhere, since that part is not actually inspected.

I agree that these drains will probably never carry water, but I decided they should at least do something.  I am going to use them as earth tubes to carry fresh air into the house.  Sherri doesn’t like the idea of carrying fresh air thru corrugated pipes because water can sit in them and cause problems (mold, humidity)…  But I also know of many success stories.  I wanted to try it out and I can always seal them up if it doesn’t work out.

The first day that we laid the drain tile, the battery died in the camera, so you don’t see how many hours it took me to get it all sloping just right.

The big hassle on the second day (Saturday) was carrying all that pea stone down into the “pit”, bucket by bucket.  We didn’t make our Saturday night deadline.  The inspector is only available for a few slots each week, so if we missed Monday for the pre-backfill inspection, we would need to put off the back-filling and schedule the inspector for Wednesday…

That was the the day my sister was coming into town…  We would need to come back and finish up then.

Insulation

You can’t see it in the video because Nick and I were working on the other side of the basement.  We initially hoped that the waterproofing would be sticky enough to “glue” it, but it was not sticky at all.  So we waited for the waterproofing to dry (2 hours cure time), and then tried to glue 2 inch thick Foamular 250 to the walls using “Liquid Nails“…  That didn’t work out at all because we couldn’t keep the stiff foam pressed against the curved wall long enough for the liquid nails to dry.  We decided to add the insulation as we back-filled…  The dirt will hold it in place very well.

Overnight work party

0

Posted on August 1, 2014 by

This week included an overnight work party at the property with some friends, Aaron and Ryan.  We headed out after work on Wednesday and got in a few hours working on the window well until it got a bit dark.  Then we had a nice camp fire (using my rocket stove) and talked until past two in the morning.

The next day, we got up before 7 and worked on Rebar until they had to go mid-morning.  At 9:00 AM, my N-12 pipe arrived and I was glad to have my friends there to help me unload it.

N12_Pipe_Delivery

After they left, I tied rebar for a while, then spent a few hours on off camera tasks like getting new tires and parts for my skid steer.  Eventually, I got back and spent the rest of the day on Electrical.

Here is the video.

Extra Info;

XPS forms?

I wanted to use a different approach for forming the window well…  Partially because I wanted to experiment with different methods and partially because the window well is more exposed to the environment and I didn’t think the metal lath and studs would be a good idea.  I originally thought I would just do it with plywood sheathing and 2x4s.

On the way out to the property, we stopped to pick up a trailer full of wood at Home Depot.  Sheathing Plywood is actually pretty expensive.  More expensive than tongue and groove 1” rigid XPS insulation…  So we switched plans on the fly and bought the XPS instead.  I also considered going with OSB, Oriented Strand Board), and bought a couple sheets, but didn’t use them.  The XPS was easy to work with and I am pretty happy with the decision.  The test will be when we shoot the shotcrete at it.  XPS is tougher than the EPS backing that I saw used with shotcrete last year, plus it is firmly attached to treated 2x4s, so I think it will be fine.

At the end of the day, I think the XPS and 2×4 approach was easier to assemble.  However, it is also more expensive, especially if you are building forms more than 8ft tall.

Curving rebar?

For curving the rebar, we tried a few things, including the rebar hickey.  The main difficulty is getting the right curvature and all in one single plane.  Bending rebar is easy, curving rebar to a precise shape takes technique.  The winning solution is shown in the video.

We stand on the rebar and pull one side up a certain amount (experience helps).  Basically, it is not really a continuous curve, but more piecewise linear.  When the raised end becomes two difficult for one person to manage, one person holds it vertical (in plane) so the other person can do a similar bend from the other end.  Due to the way that steel stays in the elastic range for a while and then yields for a permanent bend, we need to over bend it to start.   So the second step is to push it down flat, again keeping it in plane.   (an improvement I worked out on a later day was to walk it flat instead of using our hands to wrestle it down).  When we let it go, it springs back to a curve with a larger radius.

StressStrain

We had marked the radius we wanted in the sand and we set the curved rebar in the sand “template” to check it.  Some of them were right on.  If they needed any adjustment, one of us would stand at the point where things started to go off the line and the other one would pull the rebar horizontally and adjust it into shape…  The adjustment is actually so fast and easy that the timelapse camera, with a 10 second period, didn’t catch us doing it.

Electrical

Carlon Smurf ConduitThe electrical takes longer than I thought I would…  I have a plan that I am referring to, but actually wresling the blue Smurf tube (ENT conduit) into position thru all the right holes is a bit tricky.

Also, my plan didn’t take into account how many tubes would leave each box and their directions.

NEC code prohibits bending the ENT by more than 180 degrees along its length.  Each box is attached to a stud.  In many cases, the stud blocks one side of the box and leaves only 3 knock outs for the conduit to attach to.  These are in a chain, so a light switch needs one pipe to carry electricity in and other to continue the circuit to the next switch.  A third tube goes vertical toward the ceiling where we will eventually put the light fixture.  Ideally, the third tube would come from the knock out at the top of the box.  The problem happens when the power is coming from above (such as over a door).  If I run it down and around to the bottom of the box, it would exceed the 180 degrees of bending that code permits.   Instead, I must run it into the side of the box and run the “out” tube from the bottom of the box even though it actually needs to go sideways…  What if I also want to branch my circuit in a second direction?  Anyway, it takes some head scratching.  I will shot for an electrical inspection next Wednesday.

Sourcing

AA_Promo_1When you walk into Home Depot, there are lots of big signs about ordering online.  This is because they don’t have everything in the store.  For instance, none of the rebar tools on the Home Depot website are actually available on the shelf.  However, it also helps for buying cases or quantities not available in the store.   If you buy individual outlet boxes, they cost about 2 dollars each.  If you buy them in bulk, you can get a case of 50 for $38, that is about half the price.  But you can only buy the case on line.  Also, for some reason, the stores only stock 100 ft lengths of ¾” ENT tube.  The ½” tube costs quite a bit less, but only comes in 25ft lengths, and if you buy 4 of those, it costs more than the ¾” ENT tube in the 100ft roll.  The only way to get ½” tube at a good price is to buy a 200 ft roll on-line (which costs just a little more than the 100ft roll of ¾” tube).  Get it?  Good.

Problem is that it doesn’t always work out right.  I ordered a case of 50 outlets.  It was 1 case, so the quantity was listed as “1” and the amount charged was ~$38.00.  I chose to pick it up in the store.  When I went to the service desk to pick it up, they had set aside one single box for me…  I showed the girl my smartphone with the email showing I had been billed for a case, but there wasn’t much she could do except put it back as if I had not come in to pick it up.  They didn’t have any in stock at that store.  I ended up driving to two other stores in different cities trying to find enough boxes to finish my job.

I got an email today saying that if I don’t pick it up soon, the order will be canceled, so I guess I don’t need to do anything.

Earth Tube Materials

11

Posted on May 4, 2014 by

Earth Tube Material: 

When designing earth tubes, choosing the type of pipe is the first decision.  There are a variety of materials to choose from, from baked clay tiles, to steel duct work, to common PVC or the most modern HDPE plastics with anti-microbial coatings…  Perhaps I will eventually come back and put this in a table, but for now, I will just list some of the pros and cons to each.

Note that the thermal conduction properties of the material do affect the rate that heat conducts thru them, but it doesn’t seem to affect the overall performance of the earth tubes.  Partially, this may be because the total resistance to thermal conduction includes both the R value and the thickness.   Although concrete conducts heat better than plastic, concrete pipe is typically much thicker and 2 inches of concrete ends up with a thermal resistance similar to 1/4 inch of HDPE.  It is also somewhat because a somewhat stable temperature gradient is setup that eventually lets the heat thru. But the real reason the material conductivity doesn’t matter very much is because it is the conductivity of the earth that is the bottleneck.  Aluminum conducts heat very quickly, but can’t draw it from the earth any faster than a plastic pipe can.

More important aspects to consider include durability, cost, ease of installation, environmental concerns and the interior wall friction factor that has a direct effect on the frictional pressure losses of the system.

This steel earth tube helps make it affordable to heat and cool community facilities for an isolated, off-the-grid, tribe in the Yukon Territory of Canada.

Metal Ducts

Metal Ducts are commonly used in homes as part of HVAC systems, so there are a wide variety of connections/fittings available and it is not hard to put the system together yourself or to find someone to do it for you.  The prices are also reasonable and it is somewhat intuitive to believe that the metal will conduct heat better (I don’t think it actually matters since the earth limits the conduction speed anyway).

However, buried metal ducts will corrode over time, particularly in moist or acidic soil, even galvanized ducts are not recommended for burial.    Rectangular sheet metal ducts, commonly used for indoor HVAC systems, are particularly poor in an outdoor/underground environment where their shape does not help them resist earth loading.  Their joints open up and bugs, water, earth and roots get into the pipes.    While I could not find experts who recommend using regular HVAC ducting, I did find corrugated steel duct earth tubes being used in a variety of projects.  Mostly these were “earth ships” in dry areas of the southern states where corrosion is less of a problem, but the attached image is of an installation used to ventilate a large First Nations (Na-Cho Nyak Dun) tribal center in the Yukon (Canada).  No comments were made on the expected life of these ducts.

Installing Cement Earth Tubes at Aldo Leopold Center – Photo From Renew magazine

Clay or Cement

Clay or cement duct work has also been used.  The idea is that if it is good enough for drainage tile or sewer systems, it is good enough for air.   Their durability is not in question, however they are brittle and could be cracked with impact, most often during assembly when these heavy sections are lowered into the ground (typically with expensive equipment).   The rough walls of these pipes provide a lot of resistance to airflow.  The Friction factor for cement pipe is 200 times that of PVC.  This friction has a direct effect on the frictional pressure losses.  I suspect that the larger standard diameters can more than make up for the higher friction.   The surface roughness can also make cleaning them impossible.  The many joints are appreciated by bugs and mold.

It sounds like a bad idea to me, but proponents say that you can seal the joints against radon and insects while the permeability of the pipe allows moisture to escape (thwarting mold).  Because many of these materials can absorb and release moisture, they can actually solve some of the humidity problems often associated with earth tubes.

This Earth tube is approximately 600 linear feet of 2ft diameter cement pipe with rubber gasket joints. It is laid in a 5000 sq ft area, buried 10 ft below the building.

 

PVC Earth-tubes often crack during installation and need to be mended (see top pipe).

PVC (Polyvinyl Chloride)

PVC (Polyvinyl Chloride) is a frequent choice.   It is popular because you can go to any hardware store and buy as much or as little of it as you want.  There are also a wide variety of fittings available.  You can easily buy the tools and glue needed to assemble it or find someone to do that work for you.  The  downside is that PVC infamous for being one of the most hazardous consumer materials ever invented.  Not only is it toxic in is fabrication, but many of those production chemicals are not actually bonded in the plastic and can leak out over time.  No one wants dioxin or other carcinogens in their air supply.   Structurally, PVC is brittle and gets more brittle over time (especially if it spends any time in the sunlight before it is installed).   It is easily broken during installation (as testified to in the blogs of many who installed them).  Flexible rubber joints have been used to repair breaks and some recommend them as a way to prevent breaks (flex instead of crack).  Even after a successful installation, cycling temperatures cause thermal stress and micro-fractures.   The joints can catch and hold water and make the pipes difficult to clean thoroughly.

I also found it can be quite expensive (~8$/ft for 6″ Dia) compared to other options such as HDPE (~$3/ft for 6″ SDR17).  Of course, there are various grades of PVC; for instance, PVC SDR 35 (thinner) Sewer pipe can be purchased for less than 3$ per foot, but it breaks relatively easily.  The equivalent HDPE pipe (6″ DR 32.5 pipe) is much tougher and can also be purchased for less than 3$ per foot, but will require a couple more dollars per foot to fusion weld it together (if you hire someone else to install).

HDPE Pipe

HDPE (High Density PolyEthylene) was my favorite choice until I discovered Double Wall pipe (below).   It is an inert plastic with none of the health concerns of PVC.  It is also more flexible, smoother, stronger, and tougher than PVC or any other tube material I could find.  This toughness is important during installation, burial and for the life of the tubes.   HDPE handles the thermal cycling with ease.  You can bury it and it will last as long as you need it, probably forever, but it is also recyclable.   Sections of HDPE are fusion welded together in a way that results in joints that are as strong as the rest of the pipe and provide almost nowhere for water to collect.  This type of pipe has the lowest friction factor available, which has a very direct impact on reducing frictional pressure losses.

One downside to HDPE is that you may need to hire a professional with the right tools to make those fusion welds.  You can’t just pick up the pipe or the fusion tool at home depot and do it yourself (which was the main advantage of PVC).  It comes in long pipe lengths that you will need to order in bulk and then unload when it is delivered.    It also has a fairly high coefficient of thermal expansion, so if you plan to solar heat the air (as I do) flanges are recommended to prevent the HDPE from pulling itself thru the wall when it cools down.

I looked it up and noticed that the fusion welding temperature on the professional rigs was not very high (450°F), so I experimented with a piece of scrap HDPE pipe that I was given.  I tried it three ways.  First, I used my wife’s electric frying pan, which has a handy temperature dial. Second, I used my benzomatic torch directly.  Third, to get a more even application of heat, I used the benzomatic to heat a thin piece of metal on one side and then touched the plastic to the other side….  In all three cases, I was able to soften the HDPE plastic and fusion weld it with ease.  When I used the benzomatic directly, I was worried the HDPE would burn, but it didn’t.  It just softened nicely.  When I used the metal plate to transfer the heat, the plastic stuck a little (I over heated it past softening), but adding “parchment paper” solved that problem.  The electric grill worked perfectly, but is probably overkill considering the other methods worked so well.  I cut the samples up later and looked at the fusion cross sections…  They looked good, although I could have gone with less softening.  However, aligning the pipes was a little bit tricky.  It would be good to make a simple jig for that purpose.  I am pretty confident that I could do my own fusion welding for this low pressure application without hiring a pro.

 

Some people may prefer to have an expert fusion weld the HDPE pipes together…  If you do that and want to keep your HDPE installation costs down, you will need to plan ahead more.   Ordering all your HDPE for one delivery is a good idea (be ready with a fork lift to unload it), but you should also plan to have the fusion welder out for just one day.  This will require organizing to make sure your trenches are dug at the right stage (after the house is cited and perhaps after foundations are poured).   If you are planning for a geothermal ground loop, it would be at this same time also…  You would then have all the HDPE pipe laid and fused at once.  It will be important that both ends of the tubes are protected from critters from the start.  These trenches will then need to be filled in (protected) before the next construction phases can begin.

Some builders create a temporary connection box to terminate the earth tubes in while  other construction details are taken care of.  The remaining distance to create the final connection to the house would then need to be done later and would require additional expense to mobilize the fusion equipment and operator.

It is possible to buy a 500 ft coil of 4″ HDPE pipe.   At first I thought this may be a way to reduce the hassle of fusing sections together.  However, an HDPE expert I was talking to told me that wrangling a 500 ft coil is very difficult and requires special straightening equipment that heats up the pipe as it is unwound, so maybe this isn’t really an option.

 

Another downside of HDPE is the availability of the pipe.  As I noted, you can’t just walk into Home Depot and pick up a few pieces.  You will need to find a proper supplier, a supplier that is used to dealing with much bigger customers (think cities or oil companies).  The supplier may keep some HDPE pipe in stock, but there is a good chance the stuff you want won’t be…  Larger-diameter thinner-wall pipe for low-pressure flows isn’t something a lot of people are ordering.  Basically, the factory has a large extrusion pump that pushes the plastic thru a die to make the pipe.  It pushes pipe out continuously and they slice off the lengths they need.  When you order, you are asking the factory to stop the machine and switch dies for your order.  If the factory is moderately busy, they are going to need a minimum size order to even consider doing that.  It may be something like 500 or 1000 ft of pipe.  You also need to wait your turn.  Other customers are ahead of you and priority customers with larger orders may cut in line, so order early.

My local HDPE pipe distributor was very friendly and helpful, even though my job was small potatoes.  He tried to push me towards the thicker pipe they had in stock (for higher pressure water or oil pipeline applications).  He explained the factory processes and warned me that a customer order may take some time to fill.  However, the thinner pipe also takes a lot less plastic and the price is about half as much.  It will be easier to move around and easier to fusion weld, so maybe the hassle is worth it.  I will come back and let you know how it actually works out for me.

 

You can buy very expensive HDPE with an anti-microbial inner coating designed specifically for earth-tubes and marketed towards people concerned about microbial growth.  However, i suspect that the other properties of HDPE, particularly its very smooth walls and joints and inert chemical makeup, combined with proper installation, already prevents most of the problems and the expensive coating is not needed.

Google HDPE or try plasticpipe.org for more information.


Corrugated Drain Pipe

Solid Corrugated Drain Pipe for Earth Tubes

Corrugated Single Wall Drain Pipe for Earth Tubes has many good properties, but it can also hold water… So be warned!

Corrugated Drain Pipe is another polyethylene product, so, like the HDPE pipe, it is tough, long lasting, inert, etc.  However, It is much thinner than HDPE, so it is corrugated to keep it from collapsing.  This pipe is definitely the most flexible and lowest cost of all the piping options, which is why it has been so enormously popular for “budget” earth tube applications.  It is also very commonly used in perimeter drain systems used by both conventional and earth sheltered homes.

As with the other types of pipe, the 6 inch corrugated drain pipe costs more than two 4 inch pipes (probably more due to lower production than increased cost of manufacture).   You can buy “solid” corrugated drain pipe, which means it doesn’t have any holes.  This is usually a better choice than the perforated or slotted pipe usually used for drainage systems.  There is also “leech” pipe which has even larger holes and is commonly used in septic fields.  On average, 4 inch drain pipe costs less than 40 cents a foot (2012 pricing), while 6 inch can easily get up to $1.20 per foot.  You can buy large rolls, 100ft or even 200ft long.  This sort of pipe is easy to install yourself, for additional savings.

Of course, there are drawbacks…   In fact, I suspect that much of the bad press surrounding earth tubes comes from the use of this sort of pipe.   Because the pipe is corrugated, regardless of how well it is laid, water will not fully drain out to the end.  Water can sit in the corrugations.   This can be worsened if it is not laid straight, which is not always easy with coiled pipe.  

Using perforated or slotted pipe can help by letting that water out of each corrugation, but those holes are notorious for letting bugs and radon (and possibly more moisture or water) in.  Also, the factory slotted pipe has the slots on inside ridges, so there is no draining the outside ridges (I assume this is to prevent the slotted pipe from snagging while it is uncoiled).  This pipe can come with a fabric sock that will help keep plant roots and many of the larger bugs out.

Earth tube experts warn that it is better to buy solid corrugated pipe and cut your own slots.   Notch each of the outward corrugations, but only on the bottom side of the pipe, so they will drain (just notch, don’t split the length of the pipe or it will collapse).  Lay the pipe very carefully to make sure the notch is on the bottom.  The hope is that any water droplets will have a very short distance to run before they can exit the pipe.

My wife is particularly concerned about this sort of pipe and absolutely will not let me even consider it as fresh air inlets for our home… This is a concern shared by many (and protested by others).  We will be using this sort of corrugated pipe for drainage around the perimeter of our foundation.    My plans for “By-Passive Solar” include earth tubes that would not go into the house, but would instead circulate solar heated air under my umbrella.   The perimeter drains are already in a good place to do that second duty, I would simply need to lay them out a little differently so that I had a complete circuit and attachments to the solar air heater…   I might even hook them up so they can enter the house (if I want).  Design is still on going.

 

The corrugations also add wall friction ( very high surface roughness which leads directly to high frictional pressure losses) to this sort of pipe.  If you are taking it more than a hundred feet, I recommend paying extra for the 6 inch pipe  (even larger sizes would be better, but they are prohibitive expensive).   If you use a duct fan, make sure it is the high pressure centrifugal type and not the low pressure axial “booster fan” type.   It may not be practical for other reasons, but some suggest pushing the air (pressurizing the pipe) rather than pulling the air (reducing the pressure in the pipe).  This positive pressure should help keep some things out (including Radon) rather than drawing them in.

Warning: Corrugated drain pipe seems great!  It is tough, flexible, cheap, easy to install, etc. but it can also hold water (potential mold problem) so it needs to be laid very carefully.

 

Some experienced earth tube experts (such as Larry Larson) recommend these corrugated tubes (but at the larger 8 inch diameter) because they feel the corrugations help mix the air, which improves thermal transfer.  He also says you must lay them in a serpentine pattern to help with the mixing.  I assure you (see the sections on Pressure Drop and Reynolds Number calculations) that the flow will be turbulent in even the smoothest pipe.  The corrugations and serpentine path will dramatically affect pressure loss (Larson mentions that you can’t even feel the air moving).   Larson’s site goes into detail on other steps you need to take to keep mold an other potential hazards at bay.

 

Corrugated Double Wall Drain Pipe

DoubleWall_CrossSectionI am not the only one to notice the serious problem with draining corrugated pipe…  Fortunately, some of the others were in a much better position to solve the problem.  They invented “Double wall” pipe.  This is pipe that has a corrugated outer surface for strength and flexibility surrounding a smooth inner wall that drains cleanly.

Since this uses much less plastic than the solid HDPE pipe, it costs quite a bit less.  It also weighs much less and is more flexible, so it is easier to get into position.  The best part is the press fit soil tight (water tight is also available) connections that make assembly a snap.  Most brands also feature a design where the snap together mechanism works within the outside diameter.

I hunted around and found some local distributors for ADS Pipe in my area, N-12 is the product name.  They both quoted me the exact same prices, so I guess price is determined by the head office.  With the solid wall pipe, I needed an unusually thin wall so I needed to give weeks worth of notice to get my special order filled, but with the ADS N-12 drainage pipe, diameters from 4″ to 60″ are standard and I could get delivery in 3 days.  They also had a wide range of fittings such as T pipes, etc.

Spunstrand

 

is a fiberglass duct type that I recently learned about.  I have not had time to research it thoroughly, but it is used mainly in under-slab HVAC for commercial and industrial buildings.   It is available in all the diameters and with all the fittings that you would need.  I heard it was expensive, and it looks like it needs very professional installation but not sure how that cost compares to the alternatives.   I will research it more when I have time.